Câble à fibre optique multimode OM2 à 12 fibres, intérieur/extérieur, tampon serré OFNR (prix/pied)
Internal Reference :Description :
FIB-IO5-12-OM2
Référence interne:
FIB-IO5-12-OM2
Applications
-
Intra/Inter-building Backbones
-
Trench & Conduit/Duct/Tray pathways
-
Dry or wet locations
Water-blocked (dry technology), sunlight resistant indoor/outdoor tight buffer riser rated cable line offers the system designer the ultimate in premises fiber optic cable utility.
Cable can be installed
- In open spaces
- Trays
- Conduits
- Inner-ducts
- Trenches (within conduits)
- Steam tunnels
- Building riser locations.
Cable
incorporates the latest in dry-water blocking technology. This system
of water blocking eliminates the need to clean off the traditional
gel-based water-blocking compounds found in loose-tube cables. In
addition, breakout kits and or other special termination equipment
associated with loose tube OSP cables are not required. The outer jacket
is comprised of a rugged UL listed sunlight resistant polymer that
allows for the cable to be exposed to long-term direct sunlight without
the concern of material degradation.
Physical Description
- Single-unit Design (6 – 12 Fibers): the design consists of flexible tight buffer material extruded over the fiber to a diameter of 900 ìm. Multiple 900 ìm, color coded fibers are combined with aramid and water-blocking elements to obtain proper strength and water-blocking characteristics. The core construction is then covered with flame, chemical and sunlight resistance black outer jacket.
Features
- Tested and Qualified to GR-409 and GR-2961
- Exceeds TIA/EIA 568-B.3 optical performance
- Dry-block design meets Telcordia GR-20 water block requirements
- 900 ìm tight-buffered fibers
- Black, UL listed Sunlight Resistant and outer jacket
- UL/NEC Listed OFNR/FT4
- All – dielectric
Benefits
- Assurance that cable investment is maintained over the life of the system
- Future-proof fiber performance for current and future multi-gigabit applications
- Cable integrity maintained even if damage occurs to protective layers
- Direct connectorization without additional hardware
- Confidence that cable will last even with long-term exposure to direct sunlight
- Eliminates the need to purchase separate cables for OSP and indoor/riser applications
- No additional grounding materials need to be purchased
- Saves time in cable preparation
Environmental Specifications
- Riser Operation: -40°C to + 75°C
- Storage/Shipping: -40°C to + 75°C
- Installation: -20°C to + 65°C
- Crush: 10N/mm
- Impact: 6 N-m