3m (10ft) LC to ST Mode Conditioning 62.5 Micron, LSZH, Fiber Optic Patch Cable

Internal Reference :
Description :
#CABLEK:

FIZMC-LC/ST-3

    This combination does not exist.

    35.00 $ 35.0 CAD 35.00 $

    35.00 $

    Availability: In Stock
    Quantity:

    Internal Reference: FIZMC-LC/ST-3



    LC Singlemode 9/125μm Equipement to ST OM1 62.5/125μm Mode Conditioning Patch Cable


    Cablek supplies standard and customized mode conditioning patch cables (MCP) in 62.5/125 and 50/125 , which are specified for 1000BASE-LX/LH and 10GBASE-LRM transceivers transmitting in the 1300nm window and applicated over multimode plants.

    Launching a singlemode laser into the center of a multimode fiber can cause multiple signals to be generated that confuses the receiver at the other end of the fiber. These multiple signals, caused by Differential Mode Delay (DMD) effects, severely limit the cable distance lengths for operating Gigabit Ethernet. A mode conditioning patch cable eliminates these multiple signals by allowing the singlemode launch to be offset away from the center of a multimode fiber.

              Specifications
    • Connector LC to ST
    • Fiber Mode9/125μm and 62.5/125μm
    • Connector Polish UPC to UPC
    • Operating Wavelength 850nm and 1310nm
    • Insertion Loss≤0.3dB@1310nm (SM to MM Plus Connector loss)
    • Return Loss>55dB (SM connector)
    • Coupled Power Ratio 28dB≤CPR≤40dBJacket OD2.0mm
    • Jacket Material PVC
    • Durability1000 times
    • Operating Temperature-40 to 75°C
    • Storage Temperature-40 to 85°C

    • Features

      LC Equip to ST OM1 Mode Conditioning Fiber Optic Patch Cable

      Compliant with IEEE 802.3z standard, MCP Cable is specially used for singlemode and multimode interconnection and applicated over multimode plants in Gigabit Ethernet.

      Different Connector Colors Design

      Blue for singlemode and Creamy-white for multimode, different connector colors design is easier for recognition and installation.

      Low Insertion Loss Connectors

      The tightly tolerance ceramic ferrules ensure consistent low loss to make your network operate smoothly.

      Centerline Offset Splice

      It can help avoid Differential Mode Delay effects, which severely limit the cable distance lengths for operating Gigabit Ethernet.

      Mode Conditioning Patch Cable Installation over Multimode Cable Plant

      Mode Conditioning Patch Cable utilizes both singlemode and multimode fiber enabling a singlemode signal to be correctly sent through a multimode network. For this application, the singlemode end of a mode conditioning cable should always be connected to the equipment side, while the multimode end should be connected to the plant side.

      Application in Data Center

      Collocated with 1000BASE-LX or 10GBASE-LRM transceivers Mode Conditioning Patch Cable can apply to singlemode and multimode interconnection of internal Data Center.