LLR-195 50 Ohm Coax Bulk Cable
LMR 195 COAX LOW-LOSS 50 OHM COAX
ANTENNA 195 Series LOW-LOSS 50 OHM RF Transmission Coaxial Cable
Utilized in numerous applications where loss and performance supersede traditional RG58, RG8, RG213, RG223, and RG214 coaxial cables
Applications:
Mobile phone, Wi-Fi, Broadband, Satellite Antennas, Terrestrial Microwave, Medical, Military, Traffic Control, and Land Mobile Radio
Construction Specifications:
Material |
Diameter | |
Inner conductor | Solid Copper | 0.037" Nom. |
Dielectric | Foamed Polyethylene Bonded Aluminum Foil + Tinned | 0.110" Nom. |
Outer Conductor | Copper Braid | 0.139" Nom. |
Jacket | Black Polyethylene | 0.195" Nom. |
Electrical Properties:
Capacitance |
24.3 pF/ft |
Impedance |
50 Ohms |
Velocity |
80% |
Inner Conductor DC Resistance |
7.60 (Ohms/1000ft) |
Outer Conductor DC Resistance |
4.90 (Ohms/1000ft) |
Shielding Effectiveness |
90 dB |
Jacket Spark |
3,000 VAC |
Cutoff Frequency |
41 GHz |
Peak Power |
2.5 kW |
Voltage Withstand |
1,000 VDC |
Mechanical & Environmental Properties:
Minimum Bend Radius | 0.50" |
Storage Temperature | -94°F to 185°F |
Installation Temperature | -40°F to 185°F |
Operating Temperature | -40°F to 185°F |
Attenuation & Average Power (68°F):
Frequency (MHz) | Typical Attenuation (dB/100ft) | Average Power (kW) |
30 |
2.0 |
0.89 |
50 |
2.60 |
0.68 |
150 |
4.40 |
0.39 |
220 |
5.40 |
0.32 |
450 |
7.80 |
0.22 |
900 |
11.10 |
0.15 |
1500 |
14.50 |
0.12 |
1800 |
16.00 |
0.11 |
2000 |
16.90 |
0.10 |
2500 |
19.00 |
0.09 |
5800 |
29.90 |
0.06 |
Specifications
Length | 100' or 250' or 500' or 1000' |